public health authority for the most current information.
FentaNYL citrate, 10 mcg in 0.9% Sodium Chloride 1 mL Vial (10 mcg/mL), 1.5 mL Total Volume per Vial, Intravenous, Rx Only, Hospital/Office Use Only, SSM Health Care Corporation Outsourcing Facility, 1015 Bowles Ave, Fenton, MO 63026-2394. NDC: 60652-9010-1
by SSM Health Care St. Louis DBA SSM St. Clare Health Center
Reason
Lack of Assurance of Sterility: Firm did not perform process validation.
Phenylephrine HCl, 1000 mcg/10 mL, 10 mL Total Volume per syringe, Intravenous, Rx Only, Hospital/Office Use Only, This is a Compounded Drug - Not for Resale, SSM Health Care Corporation Outsourcing Facility, 1015 Bowles Ave, Fenton, MO 63026-2394. NDC: 60652-0104-1
by SSM Health Care St. Louis DBA SSM St. Clare Health Center
Reason
Lack of Assurance of Sterility: Firm did not perform process validation.
HYDROmorphone HCl 10 mg in 0.9% Sodium Chloridge, 50 mL syringe (0.2 mg/mL), Rx Only, SSM Health Care Corporation Outsourcing Facility, 1015 Bowles Ave, Fenton, MO 63026-2394. NDC: 60652-0600-2
by SSM Health Care St. Louis DBA SSM St. Clare Health Center
Reason
CGMP Deviations: Discontinuation of the Quality program by manufacturer that would assure product meet the identity, strength, quality, and purity characteristics that they are purported or represented to possess.
Succinylcholine chloride 100 mg in 5 mL syringe, Concentration: 20 mg/mL. This is a compounded injectable drug; Rx only; Hospital/office use only. SSM St. Clare Outsourcing Facility, Fenton, MO --- NDC: 88890-7536-01
by SSM Health Care St. Louis DBA SSM St. Clare Health Center
Reason
Lack of sterility assurance: Microbial growth detected during a routine simulation of the manufacturing process. No batches of distributed product have been identified as actually containing microorganisms.
Phenylephrine 1000 mcg in 0.9% Sodium Chloride 10 mL, 10 mL syringe, Concentration: 100 mcg/mL. This is a compounded injectable drug; Rx only; Hospital/office use only. SSM St. Clare Outsourcing Facility, Fenton, MO --- NDC: 88890-0104-01
by SSM Health Care St. Louis DBA SSM St. Clare Health Center
Reason
Lack of sterility assurance: Microbial growth detected during a routine simulation of the manufacturing process. No batches of distributed product have been identified as actually containing microorganisms.
Oxytocin 30 units in 0.9% Sodium Chloride 500 mL, 500 mL IV Bag, Concentration: 0.06 units/mL. This is a compounded injectable drug; Rx only; Hospital/office use only. SSM St. Clare Outsourcing Facility, Fenton, MO --- NDC: 88890-0903-01
by SSM Health Care St. Louis DBA SSM St. Clare Health Center
Reason
Lack of sterility assurance: Microbial growth detected during a routine simulation of the manufacturing process. No batches of distributed product have been identified as actually containing microorganisms.
Norepinephrine 8 mg in dextrose 5% 250 mL, 250mL IV Bag, Concentration: 0.032 mg/mL, This is a compounded injectable drug; Rx only; Hospital/office use only. SSM St. Clare Outsourcing Facility, , Fenton, MO --- NDC: 88890-0334-01
by SSM Health Care St. Louis DBA SSM St. Clare Health Center
Reason
Lack of sterility assurance: Microbial growth detected during a routine simulation of the manufacturing process. No batches of distributed product have been identified as actually containing microorganisms.
Neostigmine Methylsulfate 5 mg/5 mL, 5 mL Syringe, Concentration: 1 mg/mL. This is a compounded injectable drug; Rx only; Hospital/office use only. SSM St. Clare Outsourcing Facility, Fenton, MO --- NDC: 88890-0329-01
by SSM Health Care St. Louis DBA SSM St. Clare Health Center
Reason
Lack of sterility assurance: Microbial growth detected during a routine simulation of the manufacturing process. No batches of distributed product have been identified as actually containing microorganisms.
Morphine 50 mg in 0.9% Sodium Chloride 5 mL PCA, 50 mL Cartridge, Concentration: 1 mg/mL, This is a compounded injectable drug; Rx only; Hospital/office use only. SSM St. Clare Outsourcing Facility, Fenton, MO. --- NDC: 88887-6795-01
by SSM Health Care St. Louis DBA SSM St. Clare Health Center
Reason
Lack of sterility assurance: Microbial growth detected during a routine simulation of the manufacturing process. No batches of distributed product have been identified as actually containing microorganisms.
HYDROmorphone 10 mg in 0.9% Sodium Chloride 50 mL PCA, 50 mL Cartridge, Concentration: 0.2 mg/mL., This is a compounded injectable drug; Rx only; Hospital/office use only. SSM St. Clare Outsourcing Facility, Fenton, MO. --- NDC: 88883-0600-01
by SSM Health Care St. Louis DBA SSM St. Clare Health Center
Reason
Lack of sterility assurance: Microbial growth detected during a routine simulation of the manufacturing process. No batches of distributed product have been identified as actually containing microorganisms.
Fentanyl 2 mcg/mL and ropivacaine 0.2% in 0.9% Sodium Chloride 150 mL, 150 mL bag, This is a compounded injectable drug; Rx only; Hospital/office use only. SSM St. Clare Outsourcing Facility, Fenton, MO. --- NDC: 88883-4272-01
by SSM Health Care St. Louis DBA SSM St. Clare Health Center
Reason
Lack of sterility assurance: Microbial growth detected during a routine simulation of the manufacturing process. No batches of distributed product have been identified as actually containing microorganisms.
This page lists recalls that name SSM Health Care St. Louis DBA SSM St. Clare Health Center as the recalling firm in the official source notice. It is
not a safety rating, ranking, or statement that the company acted negligently.